Nerve Monitoring System, Salt Lake City VA Health Care System
Agency: | |
---|---|
Level of Government: | Federal |
Category: |
|
Opps ID: | NBD00159832754442842 |
Posted Date: | Sep 20, 2023 |
Due Date: | Sep 25, 2023 |
Source: | https://sam.gov/opp/619089809f... |
Follow
Active
Contract Opportunity
Notice ID
36C25923Q0969
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
NETWORK CONTRACT OFFICE 19 (36C259)
Looking for contract opportunity help?
Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.
- Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
- All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
- Updated Published Date: Sep 20, 2023 03:34 pm EDT
- Original Published Date: Sep 20, 2023 03:32 pm EDT
- Updated Date Offers Due: Sep 25, 2023 04:00 pm EDT
- Original Date Offers Due: Sep 25, 2023 04:00 pm EDT
- Inactive Policy: 15 days after date offers due
- Updated Inactive Date: Oct 10, 2023
- Original Inactive Date: Oct 10, 2023
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
-
NAICS Code:
- 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
-
Place of Performance:
Salt Lake City , UT 84148USA
Salient Characteristics for nerve monitoring system
- 1 to 4 channels that are individually and simultaneously selectable.
- Input sensitivity 5 – 10,000 μV peak-to-peak AC Coupled ± 5% at 10 mV to ± 30% at 100 mV peak-to peak AC Coupled
- Input Impedance > 10 Meg Ohm
-
Patient Isolation Wired 1,000 Vrms 60Hz
-
Measurement Range:
-
Electrodes: 0K to 2K Ohm ± 500 Ohm >2K-175K Ohm ± 20% Ground and Stim Returns
-
Electrodes: 0K to 2K Ohm ± 500 Ohm >2K-175K Ohm ± 20% Ground and Stim Returns
-
Bipolar Electrocautery Rejection Continuous Monitoring During Bipolar Cautery
- Monopolar Electrocautery (ESU) Interference Automatic detection and muting in wired or wirefree modes
-
Muting Console Input Sensitivity
-
Muting (0.6 - 2.0 Volts Vrms) Non-Muting (
-
Muting (0.6 - 2.0 Volts Vrms) Non-Muting (
-
Muting Detector Input ESU Immunity
-
ESU
-
ESU
- Stimulus Output Accuracy ± .01 mA (or ± 10% of reading at 1 K load) over Stimulus Range
- Stimulus Measurement Accuracy ± .02 mA (or ± 10% of reading at 1 K load) over Stimulus Range
- Waveform Monophasic, Bi-phasic, Alternating Polarity, or Pulse Train of square pulses
- Interpulse Interval 50uS, 100uS, 500uS, 1-5mSec
- Interphase Delay 0, 50, 100, 500, uS
Attachments/Links
Attachments
file uploads
Document | File Size | Access | Updated Date |
|
214 KB
|
Public |
Sep 20, 2023
|
|
400 KB
|
Public |
Sep 20, 2023
|
Contracting Office Address
- 6162 S WILLOW DR SUITE 300
- Greenwood Village , CO 80111
- USA
Primary Point of Contact
- Sunnie.Germaine-Pickett@va.gov
- sunnie.germaine-pickett@va.gov
- Phone Number 3037125833
Secondary Point of Contact
- Douglas Buffington
- Douglas.Buffington@va.gov
- Phone Number 9185773012
- Sep 20, 2023 03:34 pm EDTCombined Synopsis/Solicitation (Updated)
- Sep 20, 2023 03:32 pm EDT Combined Synopsis/Solicitation (Original)
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.